Poly LC Inc.
HPLC Supplies for the Life Science
PolyHYDROXYETHYL A™ - for Hydrophilic Interaction and Size Exclusion HPLC -
This neutral, polar material was developed specifically for Hydrophilic Interaction Chromatography (HILIC). HILIC is a variant of normal phase chromatography that is performed with a polar stationary phase and a partly aqueous mobile phase. This permits normal-phase separations of peptides, nucleic acids, carbohydrates, some proteins, and polar solutes in general. In comparison with other materials used for HILIC, PolyHYDROXYETHYL A™ affords sharper peaks and better selectivity and recovery. Its great polarity means less organic solvent is needed to get retention.
Use PolyHYDROXYETHYL A™ for:
- Analysis of polar small molecules for metabolomics or analysis via HILIC-MS/MS of specific small molecules (amino acids; methotrexate) in plasma or crude extracts.
- Peptide separations and mapping involving differences in polar groups (Ser-; glycopeptides; etc.).
- Multidimensional purification of synthetic and natural peptides or fractionation of really complex digests.
- HPLC of solutes that aren't soluble in aqueous media (membrane proteins;phospholipids).
- Eliminating detergents, lipids, and salts from a sample.
- Oligonucleotides and their analogs.
COLUMNS - 3 µm, 1500 Å | COLUMNS - 12 µm, 300 and 1500 Å | |||
ITEM | SIZE | ITEM | SIZE | |
051HY03-- | 50 x 1.0 mm | 204HY12-- | 200 x 4.6 mm | |
101HY03-- | 100 x 1.0 mm | 209HY12-- | 200 x 9.4 mm | |
052HY03-- | 50 x 2.1 mm | 259HY12-- | 250 x 9.4 mm | |
102HY03-- | 100 x 2.1 mm | 2521HY12-- | 250 x 21.0 mm | |
3.54HY03-- | 35 x 4.6 mm | 2550HY12-- | 250 x 50.8 mm | |
054HY03-- | 50 x 4.6 mm | |||
104HY03-- | 100 x 4.6 mm | |||
109HY03-- | 100 x 9.4 mm | |||
COLUMNS - 3 µm 300 and 1000 Å | CAPILLARIES - 5 µm, 300 and 1000Å | |||
ITEM | SIZE | ITEM | SIZE | |
051HY05-- | 50 x 1.0 mm | 050.15HY05-- | 50 mm x 150 µm | |
101HY05-- | 100 x 1.0 mm | 100.15HY05-- | 100 mm x 150 µm | |
151HY05-- | 150 x 1.0 mm | 150.15HY05-- | 150 mm x 150 µm | |
3.52HY05-- | 35 x 2.1 mm | 050.30HY05-- | 50 mm x 300 µm | |
052HY05-- | 50 x 2.1 mm | 100.30HY05-- | 100 mm x 300 µm | |
102HY05-- | 100 x 2.1 mm | 150.30HY05-- | 150 mm x 300 µm | |
202HY05-- | 200 x 2.1 mm | |||
3.54HY05-- | 35 x 4.6 mm | |||
054HY05-- | 50 x 4.6 mm | |||
104HY05-- | 100 x 4.6 mm | |||
204HY05-- | 200 x 4.6 mm | |||
109HY05-- | 100 x 9.4 mm | |||
209HY05-- | 200 x 9.4 mm | |||
259HY05-- | 250 x 9.4 mm | |||
2521HY05-- | 250 x 21.0 mm |
FORMULATING A COMPLETE ITEM NUMBER
The item numbers in this list require additional numbers at the end to designate the pore diameter:
Numbers: -006, -01, -02, -03, -05, -10, and -15 correspond to the following pore diameters:
60 Å, 100 Å, 200 Å, 300 Å, 500 Å, 1000 Å, and 1500 Å, respectively.
The item numbers in this list require additional numbers at the end to designate the pore diameter:
Numbers: -006, -01, -02, -03, -05, -10, and -15 correspond to the following pore diameters:
60 Å, 100 Å, 200 Å, 300 Å, 500 Å, 1000 Å, and 1500 Å, respectively.