Aurora Borealis Control BV
  • Home
  • Fresh of the Press News
  • Highlighted Products
  • Bibliography
  • Chromatography
  • Clinical Controls and HPLC Kits
  • Microdialysis
  • Sample Preparation Products
  • Spare Parts HPLC Instruments
  • Suppliers
  • Vials and Caps
  • Terms and conditions
  • Starpure Catalogue 2024
  • Home
  • Fresh of the Press News
  • Highlighted Products
  • Bibliography
  • Chromatography
  • Clinical Controls and HPLC Kits
  • Microdialysis
  • Sample Preparation Products
  • Spare Parts HPLC Instruments
  • Suppliers
  • Vials and Caps
  • Terms and conditions
  • Starpure Catalogue 2024

POLY LC Inc.

HPLC Supplies for the Life Science

PolyGLYCOPLEX A™ - for HILIC of Complex Carbohydrates -

 
This neutral material has the unusually high capacity needed to retain complex carbohydrates in the HILIC mode. Columns can frequently be operated with just acetonitrile and water, although charged carbohydrates may require inclusion of some salt such as ammonium acetate. These conditions are convenient for isolation of carbohydrates or direct flow to a mass spectrometer. Selectivity is good for both native glycans and derivatives such as those with the 2-aminopyridine (PA-) fluorophore. Oligosaccharide mixtures can often be resolved isocratically, although gradients are recommended for especially varied samples. Sialylated and asialo- glycans can be resolved using the same running conditions. In some cases selectivity compares favorably with that of HPAEC with PAD detection, and both running conditions and equipment maintenance are far more convenient.
 
COLUMNS - 3 µm, 1500 Å   COLUMNS - 12 µm 300 Å and 1500 Å
ITEM SIZE ITEM SIZE
051GL03-- 50 x 1.0 mm 204GL12-- 200 x 4.6 mm
101GL03-- 100 x 1.0 mm 209GL12-- 200 x 9.4 mm
052GL03-- 50 x 2.1 mm 259GL12-- 250 x 9.4 mm
102GL03-- 100 x 2.1 mm 2521GL12-- 250 x 21.0 mm
3.54GL03-- 35 x 4.6 mm 2550GL12-- 250 x 50.8 mm
054GL03-- 50 x 4.6 mm
104GL03-- 100 x 4.6 mm           
109GL03-- 100 x 9.4 mm
 COLUMNS - 5 µm, 300 Å and 1000 Å    CAPILLARIES - 5 µm, 300 Å and 1000Å
ITEM SIZE ITEM SIZE
051GL05-- 50 x 1.0 mm 050.15GL05-- 50 mm  x  150 µm
101GL05-- 100 x 1.0 mm 100.15GL05-- 100 mm  x  150 µm
151GL05-- 150 x 1.0 mm 150.15GL05-- 150 mm  x  150 µm
3.52GL05-- 35 x 2.1 mm 050.30GL05-- 50 mm  x  300 µm
052GL05-- 50 x 2.1 mm 100.30GL05-- 100 mm  x  300 µm
102GL05-- 100 x 2.1 mm 150.30GL05-- 150 mm  x  300 µm
202GL05-- 200 x 2.1 mm
3.54GL05-- 35 x 4.6 mm
054GL05-- 50 x 4.6 mm
104GL05-- 100 x 4.6 mm
204GL05-- 200 x 4.6 mm
109GL05-- 100 x 9.4 mm
209GL05-- 200 x 9.4 mm
259GL05-- 250 x 9.4 mm
2521GL05-- 250 x 21.0 mm
 
FORMULATING A COMPLETE ITEM NUMBER
The item numbers in this list require additional numbers at the end to designate the pore diameter:
Numbers: -006, -01, -02, -03, -05, -10, and -15 correspond to the following pore diameters:
60 Å, 100 Å, 200 Å, 300 Å, 500 Å, 1000 Å, and 1500 Å, respectively.

Navigation

Home Fresh of the Press News Highlighted Products Bibliography Chromatography Clinical Controls and HPLC Kits Microdialysis Sample Preparation Products Spare Parts HPLC Instruments Suppliers Vials and Caps Terms and conditions

Contact

The Netherlands
info@aurora-borealis.nl +31 (0)592 - 399 850

Openinghours

Chamber of Commerce: 04056611
VAT reg no.: NL806981866.B01

Made with ❤ by: LOYALS