Aurora Borealis Control BV
  • Home
  • Fresh of the Press News
  • Highlighted Products
  • Bibliography
  • Chromatography
  • Clinical Controls and HPLC Kits
  • Microdialysis
  • Sample Preparation Products
  • Spare Parts HPLC Instruments
  • Suppliers
  • Vials and Caps
  • Terms and conditions
  • Starpure Catalogue 2024
  • Home
  • Fresh of the Press News
  • Highlighted Products
  • Bibliography
  • Chromatography
  • Clinical Controls and HPLC Kits
  • Microdialysis
  • Sample Preparation Products
  • Spare Parts HPLC Instruments
  • Suppliers
  • Vials and Caps
  • Terms and conditions
  • Starpure Catalogue 2024

PolyLC Inc.

HPLC Supplies for the Life Science

PolyWAX LP™ - for Anion-Exchange of Proteins and Nucleic Acids -

 
PolyWAX LP™ for:
  • Isocratic separation of amino acids, peptides, and proteins.
  • Selective isolation and separation of phosphopeptides.
Most proteins have isoelectric points below 7, and are best purified or analyzed by anion-exchange chromatography. PolyWAX LP™ is a hydrophilic weak anion-exchange (WAX) material developed by PolyLC for HPLC of enzymes and other proteins. Selectivity is excellent, with high or quantitative recovery of applied biological activity. Most anion-exchange materials based on polyethyleneimine (PEI) are prepared with the conventional branched polymer. PolyWAX LP™ is prepared with linear PEI, which confers greater selectivity and recovery.

 
COLUMNS - 3µm, 1500 Å COLUMNS - 12µm, 300 and 1500 Å
ITEM SIZE ITEM SIZE
051WX03-- 50 x 1.0 mm 204WX12-- 200 x 4.6 mm
101WX03-- 100 x 1.0 mm 209WX12-- 200 x 9.4 mm
052WX03-- 50 x 2.1 mm 259WX12-- 250 x 9.4 mm
102WX03-- 100 x 2.1 mm 2521WX12-- 250 x 21.0 mm
3.54WX03-- 35 x 4.6 mm 2550WX12-- 250 x 50.8 mm
054WX03-- 50 x 4.6 mm
104WX03-- 100 x 4.6 mm
109WX03-- 100 x 9.4 mm
COLUMNS 5 µm, 300 and 1000 Å CAPILLARIES 5µm, 300 and 1000 Å
ITEM SIZE ITEM SIZE
051WX05-- 50 x 1.0 mm 050.15WX05-- 50 mm  x  150 µm
101WX05-- 100 x 1.0 mm 100.15WX05-- 100 mm  x  150 µm
151WX05-- 150 x 1.0 mm 150.15WX05-- 150 mm  x  150 µm
3.52WX05-- 35 x 2.1 mm 050.30WX05-- 50 mm  x  300 µm
052WX05-- 50 x 2.1 mm 100.30WX05-- 100 mm  x  300 µm
102WX05-- 100 x 2.1 mm 150.30WX05-- 150 mm  x  300 µm
202WX05-- 200 x 2.1 mm
3.54WX05-- 35 x 4.6 mm
054WX05-- 50 x 4.6 mm
104WX05-- 100 x 4.6 mm
204WX05-- 200 x 4.6 mm
109WX05-- 100 x 9.4 mm
209WX05-- 200 x 9.4 mm
259WX05-- 250 x 9.4 mm
2521WX05-- 250 x 21.0 mm
 
FORMULATING A COMPLETE ITEM NUMBER
The item numbers in this list require additional numbers at the end to designate the pore diameter:
Numbers: -006, -01, -02, -03, -05, -10, and -15 correspond to the following pore diameters:
60 Å, 100 Å, 200 Å, 300 Å, 500 Å, 1000 Å, and 1500 Å, respectively.

Navigation

Home Fresh of the Press News Highlighted Products Bibliography Chromatography Clinical Controls and HPLC Kits Microdialysis Sample Preparation Products Spare Parts HPLC Instruments Suppliers Vials and Caps Terms and conditions

Contact

The Netherlands
info@aurora-borealis.nl +31 (0)592 - 399 850

Openinghours

Chamber of Commerce: 04056611
VAT reg no.: NL806981866.B01

Made with ❤ by: LOYALS