Aurora Borealis Control BV
  • Home
  • Fresh of the Press News
  • Highlighted Products
  • Bibliography
  • Chromatography
  • Clinical Controls and HPLC Kits
  • Microdialysis
  • Sample Preparation Products
  • Spare Parts HPLC Instruments
  • Suppliers
  • Vials and Caps
  • Terms and conditions
  • Starpure Catalogue 2024
  • Home
  • Fresh of the Press News
  • Highlighted Products
  • Bibliography
  • Chromatography
  • Clinical Controls and HPLC Kits
  • Microdialysis
  • Sample Preparation Products
  • Spare Parts HPLC Instruments
  • Suppliers
  • Vials and Caps
  • Terms and conditions
  • Starpure Catalogue 2024

Poly LC Inc.

HPLC Supplies for the Life Science

PolyPROPYL A™ - for Hydrophobic Interaction Chromatography (HIC) of Proteins and Peptides -

 
HIC materials separate proteins on the basis of hydrophobic character, as does RPC. However, HIC uses totally aqueous buffers, retaining tertiary structure and biological activity. Selectivity is generally superior to that of RPC for proteins and polypeptides large enough to have significant secondary or tertiary structure. Typically, a sample is eluted with a decreasing gradient of a salt such as a sulfate or phosphate. Proteins elute in order of increasing surface hydrophobicity. Surfactants (e.g., CHAPS; octylglucoside) can be added to the mobile phase if necessary. The relative hydrophobic character of PolyPROPYL A™, PolyETHYL A™ and PolyMETHYL A™ is 100, 60 and 15, resp. HIC has greater sensitivity than other modes to the location of a modification or residue difference, especially (but not necessarily) if it involves a nonpolar group.
Use these HIC materials for:
  1. Multidimensional protein purification (suggested sequence: Ion-exchange - [add salt to collected fractions] - HIC).
  2. Purification of polypeptides (e.g., venoms and glycopeptides).
  3. Characterization of antibodies.
  4. QC analysis of proteins differing in the polarity of a single residue or modified positional variants.

COLUMNS - 3µm, 1500 Å COLUMNS - 12µm, 300 and 1500 Å
ITEM SIZE
ITEM SIZE
051PR03-- 50 x 1.0 mm 204PR12-- 200 x 4.6 mm
101PR03-- 100 x 1.0 mm 209PR12-- 200 x 9.4 mm
052PR03-- 50 x 2.1 mm 259PR12-- 250 x 9.4 mm
102PR03-- 100 x 2.1 mm 2521PR12-- 250 x 21.0 mm
3.54PR03-- 35 x 4.6 mm 2550PR12-- 250 x 50.8 mm
054PR03-- 50 x 4.6 mm
104PR03-- 100 x 4.6 mm
109PR03-- 100 x 9.4 mm
COLUMNS 5 µm, 300 and 1000 Å CAPILLARIES 5µm, 300 and 1000 Å
ITEM SIZE ITEM SIZE
051PR05-- 50 x 1.0 mm 050.15PR05-- 50 mm  x  150 µm
101PR05-- 100 x 1.0 mm 100.15PR05-- 100 mm  x  150 µm
151PR05-- 150 x 1.0 mm 150.15PR05-- 150 mm  x  150 µm
3.52PR05-- 35 x 2.1 mm 050.30PR05-- 50 mm  x  300 µm
052PR05-- 50 x 2.1 mm 100.30PR05-- 100 mm  x  300 µm
102PR05-- 100 x 2.1 mm 150.30PR05-- 150 mm  x  300 µm
202PR05-- 200 x 2.1 mm
3.54PR05-- 35 x 4.6 mm
054PR05-- 50 x 4.6 mm
104PR05-- 100 x 4.6 mm
204PR05-- 200 x 4.6 mm
109PR05-- 100 x 9.4 mm
209PR05-- 200 x 9.4 mm
259PR05-- 250 x 9.4 mm
2521PR05-- 250 x 21.0 mm
 
FORMULATING A COMPLETE ITEM NUMBER
The item numbers in this list require additional numbers at the end to designate the pore diameter:
Numbers: -006, -01, -02, -03, -05, -10, and -15 correspond to the following pore diameters:
60 Å, 100 Å, 200 Å, 300 Å, 500 Å, 1000 Å, and 1500 Å, respectively.

Navigation

Home Fresh of the Press News Highlighted Products Bibliography Chromatography Clinical Controls and HPLC Kits Microdialysis Sample Preparation Products Spare Parts HPLC Instruments Suppliers Vials and Caps Terms and conditions

Contact

The Netherlands
info@aurora-borealis.nl +31 (0)592 - 399 850

Openinghours

Chamber of Commerce: 04056611
VAT reg no.: NL806981866.B01

Made with ❤ by: LOYALS