Recipe

Methylmalonic Acid 

Methylmalonic Acid in Serum / Plasma / Urine, advanced
 
Methylmalonic acid (MMA) serves for the assessment of the vitamin B12 status. Vitamin B12 deficiency leads to an increased MMA concentration in plasma, serum and urine. Our new ClinMass® Complete Kit enables a fast and reliable MMA analysis from all three matrizes. For serum and plasma samples the sample preparation consists of a single pipetting step. The sample matrix is removed by precipitation while the internal standard IS (d3-MMA) is added. Urine samples can be injected directly after dilution and IS addition. The subsequent LC-MS/MS analysis is performed within a 3 min injection interval only. The isobar component succinic acid, which may interfere with MMA, is separated reliably to avoid false positive results. Calibration and quality control is performed in a convenient and cost-efficient way. The method is fully validated using only one (serum) calibration and control set for all three sample matrices (ClinCal® 4-Level Calibrator Set and ClinChek® Controls.
 
Test Data LC-MS/MS Parameters
Linearity: LC-Parameters
-Serum, Plasma up to 67745 nmol/l Gradient pump: Mobile Phase A / B 
-Urine up to 1426200 nmol/l (0.6 ml/min)
LLOD: Injection volume:: 5 - 10 µl
-Serum, Plasma 15 nmol/l Injection interval:: 3.0 min
-Urine 391 nmol/l Column heater: 40 °C
LLOQ: MS-Parameters
-Serum, Plasma 25 nmol/l Ion-Source: ESI
-Urine 651 nmol/l MS/MS-Mode: MRM
Intraassay precision: 4.3 %
Interassay precision: 5.1 %